Page
113
of
125
Bus Element Bit
0-32
Polarity
N.O.,
N.C.
Mode
Normal,
Timed,
Flash
Time Width Offset Input
Bus
Input
Element
Input
Bit
√
√
√
√
The “Torque (x100)” output assignment will output the final torque value of the most recent rundown.
The value will be cleared to 0 at the start of a new fastening cycle or a Job reset. At the end of the
fastening cycle the final torque will be multiplied by 100, truncated to an integer and output.
Angle
Supported Feature
Bus Element Bit
0-32
Polarity
N.O.,
N.C.
Mode
Normal,
Timed,
Flash
Time Width Offset Input
Bus
Input
Element
Input
Bit
√
√
√
√
The “Angle” output assignment will output the final angle value of the most recent rundown. The value
will be cleared to 0 at the start of a new fastening cycle or a Job reset.
Rundown Saved to FTP Server
Supported Feature
Bus Element Bit
0-32
Polarity
N.O.,
N.C.
Mode
Normal,
Timed,
Flash
Time Width Offset Input
Bus
Input
Element
Input
Bit
√
√
√
√
The “Rundown Saved to FTP Server” output assignment will output the ID of the last rundown that was
saved to the FTP server.
Fastener Removed
Supported Feature
Bus Element Bit
0-32
Polarity
N.O.,
N.C.
Mode
Normal,
Timed,
Flash
Time Width Offset Input
Bus
Input
Element
Input
Bit
√
√
√
√
√
The “Fastener Removed” output assignment will go active when a fastener is removed by the operator.
The controller must be configured to report disassembly for this output to work. It will go inactive when
the next fastening is started (the torque exceeds the threshold value) or a Job reset.
Spindle Ok
Supported Feature
Bus Element Bit
0-32
Polarity
N.O.,
N.C.
Mode
Normal,
Timed,
Flash
Time Width Offset Input
Bus
Input
Element
Input
Bit
√
√
√
√
√
The “Spindle Ok” output assignment will go active at the completion of multi-spindle fastening if all
spindles have an OK. It will go inactive when the next fastening is started (the torque exceeds the
threshold value) or a Job reset.
Spindle NOk