Page
41
of
125
Jobs
“ Enabled” display and button function:
Secondary Display.
PSet/Job display and
Increment/Decrement buttons.
Toggle button: PSet/Job functions.
•
Increment and Decrement buttons change the job sequence. The pset number will
change and job sequence number on
secondary display
will change if jobs are enabled.
•
Holding the toggle button will display will display the Job number, while pressing
increment or decrement buttons will change it. The two numbers on the PSet/Job display
will be separated by decimals.
•
Pressing the toggle button will change
secondary display
between:
o
Units of measure
o
Ethernet 1 IP address
o
Ethernet 2 IP address
o
System port IP address
o
Angle report
o
Bolt count
o
Job sequence
NOTE:
Job sequence shows which PSet you are currently on in the job (this is not the pset
number). The first pset in the job is always job sequence 1, and the next is 2, etc.
Bolt count is shown as current bolt count out of total number of bolts. Example:
If you have
3
total bolts. When you start the job you will see 0.3. After one rundown you will see 1.3 and then
2.3 on the next run and so on until the job is completed.