Page
109
of
125
√
√
√
√
√
The “Fastening Aborted” output assignment will go active at the completion of a fastening that was
aborted by the system. It will go inactive when the next fastening is started (the torque exceeds the
threshold value) or a Job reset.
Fastening Stopped
Supported Feature
Bus Element Bit
0-32
Polarity
N.O.,
N.C.
Mode
Normal,
Timed,
Flash
Time Width Offset Input
Bus
Input
Element
Input
Bit
√
√
√
√
√
The “Fastening Stopped” output assignment will go active at the completion of a fastening that was
stopped by the user. It will go inactive when the next fastening is started (the torque exceeds the
threshold value) or a Job reset.
Batch Complete
Supported Feature
Bus Element Bit
0-32
Polarity
N.O.,
N.C.
Mode
Normal,
Timed,
Flash
Time Width Offset Input
Bus
Input
Element
Input
Bit
√
√
√
√
√
The “Batch Complete” output assignment will go active at the completion of a fastening that satisfies
the bolt count of a Job sequence. It will go inactive when the next fastening is started (the torque
exceeds the threshold value) or the job is reset.
Job Complete
Supported Feature
Bus Element Bit
0-32
Polarity
N.O.,
N.C.
Mode
Normal,
Timed,
Flash
Time Width Offset Input
Bus
Input
Element
Input
Bit
√
√
√
√
√
The “Job Complete” output assignment will go active at the completion of a fastening that satisfies all
the sequences. It will go inactive when the next fastening is started (the torque exceeds the threshold
value) or the job is reset.
Error
Supported Feature
Bus Element Bit
0-32
Polarity
N.O.,
N.C.
Mode
Normal,
Timed,
Flash
Time Width Offset Input
Bus
Input
Element
Input
Bit
√
√
√
√
√
The “Error” output assignment will be active while the controller has an error.
Tool Start Switch
Supported Feature
Bus Element Bit
0-32
Polarity
N.O.,
N.C.
Mode
Time Width Offset Input
Bus
Input
Element
Input
Bit