Page
71
of
125
4.8.1 Controller Overview
•
Model Number:
Model Number of the controller.
•
Serial Number:
Serial Number of the controller.
•
Type:
Type of controller-
IEC – Intelligent Electric Controller
IEC4W – Intelligent Electric Controller 4 Mobile
Application:
Current Application software version.
Firmware:
Current Firmware software version.
Servo:
Current Servo Drive
Available Hardware:
Available hardware on the controller.
4.8.2 Controller Status
Shows “Live” status of controller, voltages, active faults and
temperature.
Power Supplies:
Alarm icon will appear on controller console
and under “Active Faults” (see below) if any of these values
are out of range:
•
5 VDC :
Represents voltage from 5V power supply
powering controller electronics.
•
9 VDC:
Represents voltage from 9V power supply
powering Tool electronics.
•
24 VDC:
Represents voltage from 24V power supply.
Value is reported as on or off (.0-24.0 volts) and is for
external use via 24V I/O port.
•
1.8 VDC:
Represents controller electronics internal 1.8V
Bus voltage.
•
3.3V DC:
Represents controller electronics internal 3.3V
Bus voltage.
•
DC Bus:
Value represents voltage supplied to tool motor
while running.
•
CPU Temperature (deg C):
Represents temperature inside
controller measured in Celsius.
•
Active Faults:
Any tool/ controller faults will be shown in this
area.