4.8.3 Tool Overview
This “
read only”
screen gives an overview of the tool
connected to the controller. The information is stored
in the memory on the Tool ID board (TID).
•
Model Number:
Model number of tool connected
to controller.
•
Serial Number:
Serial number of tool connected to
controller.
•
Cycle Count:
Number of fastening cycles tool has
performed since counter was reset.
•
Max Speed (RPM):
Maximum free speed of tool
output.
•
Max Torque (Nm):
Maximum torque output of tool.
_____________________________________________________________________________________________
The following information is used internally by AcraDyne Technicians and not generally relevant
to the end user:
•
Gear Ratio After Tranducer:
Any gearing between transducer and tool output.
•
Gear Inversion:
1= Tool Output rotates same direction as motor. -1= Tool Output rotates in
opposite direction as motor. (Example: Tube nut tools typically show -1 for gear inversion)
•
Ext. Multiplier:
Gear ratio of external “after market” multiplier.
•
Pulses/Rev Output:
Number of motor hall pulses that occur per one revolution of motor
Output.
•
Transducer Full Scale:
Full scale torque rating of transducer