Step 7
The RNDIS Kitl device is now installed and ready for use.
--------------------------------------------------------------------------------------------------------------------------------------------
Issue:
DC Bus High Voltage Warning when using an HT tool
Solution:
Adding a Brake Stop of 0.5 to 1.0 Second stage to the end of the rundown should eliminate this
issue.