4.5.1.7 Tubenut
Tubenut Homing Parameters:
Homing Configuration:
Two options are available-
•
Release and Repress:
Socket will return Home on release
and repress of main lever.
NOTE:
If the main lever is released while homing in this
configuration the tool will stop and will continue to Home
once the lever is repressed.
•
Release:
Socket will return Home upon release of main
lever.
Speed (RPM):
The speed in RPMs which a tubenut tool will
return to the open position (default 50 RPM).
Acceleration (kRPM/s):
Rate at which tool is set to ramp up
to maximum homing RPM.
Reverse Dwell Time:
Amount of time before Output attempts
to return Home, after Home command is initiated (default
500ms).
Hold at Home Dwell Time:
Amount of time Output is held at Home position (default 500ms).
Retry Home when Disabled:
This will allow a retry of the tube-nut homing sequence (by releasing then repressing the lever)
even if the controller has been disabled or the stop input is on
.
NOTE:
Output is held at Home for the Home Dwell Time to prevent socket from bouncing back to
partially closed position.
4.5.1.8 Past Service and Calibration
Service Past Due:
Four options are available.
No Action
:
No Action will be taken.
Log Error
:
Errors will be saved on Service Log.
Display Error:
Calibration/Service message will appear on
screen between each rundown. Tool remains functional.
Disable Tool: Disable tool in preset Service period. Exceeded
(date/time) LED warning appears on the controller.