Page
26
of
125
AC-TM Angle Control Torque Monitor Stage
Control strategy in which the tool stops when
Angle
Target
is reached or
Torque High Limit
is exceeded.
Rundown is considered to be successful (Accept) if l
the stage peak torque value falls within range specified
by torque upper and lower limits and final angle value
falls within the range specified by
Angle High Limit
and
Angle Low Limit
parameters.
Angle High:
Maximum allowed angle rotation in
degrees.
Angle Target:
Angle target desired.
Angle Low:
Minimum allowed angle rotation in degrees.
Reference:
(drop down menu)
Overall Angle:
Angle is measured starting from
lever/trigger
pull.
In-cycle Angle:
Angle is measured from In-cycle value
(determined in PSet screen).
Stage Angle:
Angle is measured from Reference
Torque.
Reference Torque:
If Stage Angle is selected, this will be
the start point (in Torque) at which angle is monitored.
NOTE:
Set Reference Torque to zero if you want Stage
Angle measured from the begining of the stage.
Torque Bailout:
Determines when to stop the tool based
on torque value during any Angle Torque Bailout value
should be equal or greater than High Torque.
Torque High:
Upper control limit of the rundown.
Torque Low:
Lower control limit of the rundown.
Max (RPM):
Tool Output speed target.
Acceleration(kRPM/s):
How quickly the tool will change speed. The lower the value the slower
the accleration (see 4.2.1.1 for advanced description).
Stage Timeout:
Maximum allowable time in this stage. If time is
exceeded, the tool will stop and the Rundown will be
terminated.
AC TM Stage
Angle
Torque
High Limit
Low Limit
H
ig
h L
im
it
Lo
w
L
im
it
Ta
rg
et