P: Torque Pass/Fail
•
‘P’ = Pass, ‘F’ = Fail
HHHHH: Torque High Limit
•
Units selected in the PSet X10
LLLLL: Torque Low Limit
•
Units selected in the PSet X10
TTTTT: Torque Result
•
Units selected in the PSet X10
P
: Angle Pass/Fail
•
‘P’ = Pass, ‘F’ = Fail
HHHHH
: Angle High Limit
•
Degrees
LLLLL
: Angle Low Limit
•
Degrees
AAAAA
: Angle Result
•
Degrees
NAC%: Message End
CR: Carriage return control character
LF: Line feed control character
NULL*: Null control character (*if option is selected)
•
UEC Serial Format (matches UEC 4800 and Gen3):
o
# 1 P BB TTT.T
AAAA
PPPP 0000 J CR NULL*
#: Message Start
1: Spindle Number (Always 1)
P: PSet
•
PSet(‘1’ – ‘9’) for PSets 1-9, (‘A’ – ‘Z’) for PSets 10-35
BB: Job Bolt Count
•
Total number of accepts during the Job
TTT.T: Torque Result
•
Units selected in the PSet
AAAA
: Angle Result
•
Degrees
PPPP: Pulse Count
0000
J: Judgment
•
‘@’ = Overall Pass, ‘H’ = Low Torque, ‘I’ = High Torque, ‘J’ = Low
Angle, ‘K = High Angle, ‘G’ = Fault During Fastening
CR: Carriage return control character
NULL*: Null control character (*if option is selected)