7.1 Stop Codes
If a Stop condition is detected that prevents the tool from running, a code will appear on the
LED display. Any active stop conditions are also displayed on the RUN screen.
CODE
ICON
Description
IO
Stopped or Disabled from Physical 24 volt IO input
ABUS
Stopped or Disabled from ANYBUS
MODB
Stopped or Disabled from Modbus
EIP
Stopped or Disabled from Ethernet IP
RTU
Stopped or Disabled from Modbus RTU
OP
Stopped or Disabled from Open Protocol
OP
Lost Open Protocol Connection
REV
Disassembly Disabled
ARM
Tool Requires Arming – MFB button configured to enable the
tool to run.
JOB
Job Sequence Complete
JOB
Job Complete
JOB
XML Count Complete
LOR
Locked on Reject
BRCD
Bar Code ID scan required to enable tool
SRVC
Tool Disabled For Service - Tool service or calibration interval
has expired
INVP
Invalid PSet - Parameter set number for a non-existent Pset has
been selected to run. Most likely via one of the following
methods:
o
Job
o
MFB
o
IO
INVP
PSet outside of Job - Parameter set number outside of the job
has been selected. Most likely via one of the following
methods:
o
MFB
o
IO
INVJ
Invalid Job - Job number for a non-existent Job has been
selected to run. Most likely via one of the following methods:
o
MFB
o
IO
PSET
PSet Mismatch
SPND
Spindle Not Configured – Spindle selected to run from a Multi-
Spindle Job has not been configured