Page
28
of
125
Delay Stage
Delay between Stages:
Time the tool stops and waits before
proceeding to the next stage. Default is 0.2 (sec).
Time Delay (sec):
Total time in seconds the tool stops and
waits before proceeding to the next stage.
Ergo Stop Stage
Ramps cut-off power when fastening achieves Target Torque
or Target Angle value. This feature reduces torque reaction
to the operator in a hand-held tool as final torque or angle is
achieved.
Torque Current Reduction:
Amount in (percent) to reduce the
current to the motor.
Ramp Down Time:
Total time to ramp down to zero current/torque.
Brake
Stop Stage
Used for active braking of tool. It is helpful in applications
where a high RPM tool is used and possible overshoot of
Target Torque or Angle is possible.
Brake Hold Time (sec):
Amount of time that brake is
applied.