![ABB ACS550-01 Скачать руководство пользователя страница 236](http://html.mh-extra.com/html/abb/acs550-01/acs550-01_user-manual_2977236.webp)
236
ACS550 User’s Manual
Technical Data
Air Flow, 380…480 Volt Drives
The following table lists heat loss and air flow data for 380…480 Volt drives.
-07A5-2
R1
81
276
44
26
-012A-2
R1
116
404
44
26
-017A-2
R1
161
551
44
26
-024A-2
R2
227
776
88
52
-031A-2
R2
285
373
88
52
-046A-2
R3
420
1434
134
79
-059A-2
R3
536
1829
134
79
-075A-2
R4
671
2290
280
165
-088A-2
R4
786
2685
280
165
-114A-2
R4
1014
3463
280
165
-143A-2
R6
1268
4431
405
238
-178A-2
R6
1575
5379
405
238
-221A-2
R6
1952
6666
405
238
-248A-2
R6
2189
7474
405
238
Drive
Heat Loss
Air Flow
ACS550-x1-
Frame Size
W
BTU/Hr
m
3
/h
ft
3
/min
-03A3-4
R1
40
137
44
26
-04A1-4
R1
52
177
44
26
-05A4-4
R1
73
249
44
26
-06A9-4
R1
97
331
44
26
-08A8-4
R1
127
433
44
26
-012A-4
R1
172
587
44
26
-015A-4
R2
232
792
88
52
-023A-4
R2
337
1150
88
52
-031A-4
R3
457
1560
134
79
-038A-4
R3
562
1918
134
79
-044A-4
R4
667
2276
280
165
-059A-4
R4
907
3096
280
165
-072A-4
R4
1120
3820
280
165
-077A-4
R5
1295
4420
168
99
-096A-4
R5
1440
4915
168
99
-124A-4
R6
1940
6621
405
238
-157A-4
R6
2310
7884
405
238
-180A-4
R6
2810
9590
405
238
-195A-4
R6
3050
10416
405
238
Drive
Heat Loss
Air Flow
ACS550-x1-
Frame Size
W
BTU/Hr
m
3
/h
ft
3
/min