12.3 List of Parameters
12-29
12
Appendix
* Used when the software version is 32 or later.
Parameter
No.
Name
Setting Range
Units
Factory
Setting
Setting
Validation
Reference
Section
Pn003
Function Selection Application Switches 3
−
−
0002
After
restart
−
Pn004
Reserved (Do not change)
0000 to 1110
−
0000
Immedi-
ately
−
Pn005
Reserved (Do not change)
−
−
0000
Immedi-
ately
−
Pn100
Speed Loop Gain
1 to 2000
1 Hz
40
Immedi-
ately
9.3.4
Pn101
Speed Loop Integral Time Constant
15 to 51200
0.01 ms
2000
Immedi-
ately
9.3.5
Pn102
Position Loop Gain
1 to 2000
1/s
40
Immedi-
ately
9.3.3
Pn103
Moment of Inertia Ratio
0 to 10000
(0 to 20000)
*
1%
0
Immedi-
ately
9.2.6
9.3.3
Pn104
2nd Speed Loop Gain
1 to 2000
1 Hz
40
Immedi-
ately
9.4.9
Pn105
2nd Speed Loop Integral Time Constant
15 to 51200
0.01 ms
2000
Immedi-
ately
9.4.9
Pn106
2nd Position Loop Gain
1 to 2000
1/s
40
Immedi-
ately
9.4.9
Pn107
Bias
0 to 450
1 min
-1
0
Immedi-
ately
9.4.6
Pn108
Bias Width Addition
0 to 250
1 reference
unit
7
Immedi-
ately
9.4.6
Pn109
Feed-forward
0 to 100
1%
0
Immedi-
ately
9.4.1
0
1
2
3
4
5
6
7
Motor speed: 1 V/100 min
-1
Speed reference: 1 V/100 min
-1
Internal torque reference: 1 V/100%
Position error: 0.05 V/1 reference unit
Position error: 0.05 V/100 reference units
Reference pulse frequency (converted to min
-1
): 1 V/100 min
-1
Motor speed
×
4: 1 V/25 min
-1
Motor speed
×
8: 1 V/12.5 min
-1
Reserved (Do not change)
Analog Monitor 1 Torque Reference Monitor
(Refer to "9.5 Analog Monitor.")
0 to F
Same as Analog Monitor 1 Torque Reference Monitor
Analog Monitor 2 Speed Reference Monitor
(Refer to "9.5 Analog Monitor.")
4th
digit
3rd
digit
2nd
digit
1st
digit
n.
8 to F
Reserved (Do not change)
Reserved (Do not change)