5 Specifications and Dimensional Drawings of Cables and Peripheral Devices
5.8.14 DC Reactor for Harmonic Suppression
5-80
5.8.14 DC Reactor for Harmonic Suppression
(1) Specifications
DC reactor for harmonic suppression is handled by Yaskawa Controls Co., Ltd.
If necessary for harmonic suppression, connect a DC reactor to the SERVOPACK. Note that no terminal for con-
necting a DC reactor is provided to the 6.0 kW or more SERVOPACKs.
Refer to the table below for selecting a DC reactor according to the SERVOPACK capacity. For the connection
method, refer to
6.4.8 DC Reactor for Harmonic Suppression
.
(2) Dimensional Drawings
Applicable
SERVOPACK Model
SGDM-
DC Reactor
Model
DC Reactor Specifications
Inductance
(mH)
Rated
Current
(A)
Single-phase
100 V
A3BD, A3BDA
−
−
−
A5BD, A5BDA
01BD, 01BDA
X5063
10.0
1.8
02BD, 02BDA
X5062
4.7
3.5
Single-phase
200 V
A3AD, A3ADA
−
−
−
A5AD, A5ADA
01AD, 01ADA
X5071
40.0
0.85
02AD, 02ADA
X5070
20.0
1.65
04AD, 04ADA
X5069
10.0
3.3
Three-phase
200 V
05AD, 05ADA
X5061
2.0
4.8
08AD, 08ADA
10AD, 10ADA
15AD, 15ADA
X5060
1.5
8.8
20AD, 20ADA
30AD, 30ADA
X5059
1.0
14.0
50ADA
X5068
0.47
26.8
DC Reactor
Model
Dimensions in mm
Approx.
Mass
kg
A
B
C
D
E
F
G
φ
H
φ
I
X5059
50
74
125
140
35
45
60
5
5.3
1.1
X5060
40
59
105
125
45
60
65
4
4.3
1.0
X5061
35
52
80
95
35
45
50
4
4.3
0.5
X5062
40
59
100
120
40
50
55
4
4.3
0.9
X5063
35
52
90
105
35
45
50
4
4.3
0.6
X5068
50
74
125
155
53
66
75
5
6.4
1.9
X5069
40
59
105
125
45
60
65
4
4.3
1.0
X5070
40
59
100
120
35
45
50
4
4.3
0.8
X5071
35
52
80
95
30
40
45
4
4.3
0.5
4
×
φ
H
Notch
A
B
D
G
E
F
φ
I
C
Units: mm
1 2
Summary of Contents for Sigma-II Series
Page 384: ...8 3 8 Operation...