12 Appendix
12.1.3 Calculating the Required Capacity of Regenerative Resistors
12-14
(3) SERVOPACK’s Absorbable Energy
The following diagrams show the relationship between the SERVOPACK’s input power supply voltage and its
absorbable energy.
• 100-V SERVOPACKs
• 200-V SERVOPACKs
Model: SGDM-
AC Input Power Supply Voltage (Vrms)
0
6
8
12
18
14
4
2
10
16
100
110
120
90
A5BD to 02BD
A5BDA to 02BDA
A3BD, A3BDA
Absorbable Energy (J)
Model: SGDM-
0
20
100
120
40
60
80
200
220
240
180
260
20AD, 20ADA
15AD, 15ADA
01AD to 04AD
01ADA to 04ADA
05AD to 10AD
05ADA to 10ADA
A3AD, A5ADA
A5AD, A5ADA
30AD, 30ADA
AC Input Power Supply Voltage (Vrms)
Absorbable Energy (J)
300
400
600
200
100
500
Model: SGDM-
700
0
200
220
240
180
260
60ADA
75ADA
50ADA
1AADA
1EADA
AC Input Power Supply Voltage (Vrms)
Absorbable Energy (J)
Summary of Contents for Sigma-II Series
Page 384: ...8 3 8 Operation...