Maintenance 7 - 8
Disconnect the cable from the Drive to the front panel mounted Digital Operator at the Drive end of the cable.
If a LonWorks option card is present, leave all the wires connected to the option card, disconnect the option card ground wire
at the Drive end and remove the option card from the Drive.
Remove the ribbon cable connector at CN8. Do this carefully by pulling down evenly on both sides of the connector.
Fig 7.5 Removing the Ribbon Cable at CN8
The power terminal block for the three phase input and output power connections is not removable. All connections to the
power terminal block must be removed. Do not overlook the Drive ground wire. It is behind other wiring and will probably be
removed last. Observe the wire and terminal markings for all power wires, to ensure correct re-wiring to the new Drive. The
wires are labeled from the factory, but re-label any wires where labels may no longer be legible. Refer to Chapter 2 Electrical
Installation and the schematic diagram that was shipped with the original Bypass unit.
Once all wiring has been disconnected from the Drive, the Drive is ready to be removed from the enclosure.
Drives located in Bypass units are mounted differently than stand alone drives. A Drive in a Bypass unit is mounted such that
the heat sink is external to the enclosure. Mounting brackets are located on the top and bottom of the Drive, between the Drive
and the Drive’s heat sink. These brackets are bolted to the Bypass back panel with the heat sink projecting through an opening
in the back panel.
Fig 7.6 Drive Top Mounting Bracket
Connector
CN8
DC Bus Charge
Indicator Location
Drive Top Bracket
Summary of Contents for E7LBA002
Page 1: ...E7L Drive Bypass Technical Manual Model E7L Document Number TM E7L 01 ...
Page 8: ...Introduction vi Notes ...
Page 12: ...Table of Contents x Notes ...
Page 54: ...Electrical Installation 2 22 Wiring Diagram ...
Page 55: ...Electrical Installation 2 23 ...
Page 87: ...Start Up and Operation 4 9 Notes ...
Page 202: ...Diagnostic Troubleshooting 6 30 Notes ...
Page 248: ...Capacity Related Parameters B 6 Notes ...
Page 279: ...Communications D 27 Note ...
Page 280: ...Communications D 28 ...
Page 292: ...Spare Parts F 6 ...
Page 304: ...Index 12 ...
Page 305: ......