8.4 SERVOPACK Parameter Management and Editing
8-17
Servo Drive Management
8.4
SERVOPACK Parameter Management and Editing
Sometimes you may need to change SERVOPACK parameters for servo adjustments, machine operation test-
ing during trial operations, or other tasks.
For this reason, it is useful to have a way to change SERVOPACK parameters from the host controller GUI.
The following items and actions are required to edit SERVOPACK parameters from the host controller.
• A GUI to select the axis for which to display parameters
• Reading the parameters from the target SERVOPACK with the Read SERVOPACK Parameter
(SVPRM_RD: 40 hex) command
• Displaying the parameter number and the current set value on the host controller GUI (You might want to
display parameters for multiple axes at the same time.)
• The ability to select a parameter with the cursor and change the current set value, then write the new value to
the SERVOPACK with the Write SERVOPACK Parameter (SVPRM_WR: 41 hex) command
Use another GUI design to create the GUI for the host controller.
SERVOPACK parameter management and editing is performed for machine setup and maintenance.
Protect all SERVOPACK parameter management and editing GUIs with a password or other security measure
so that only authorized users can use them.
Observe the following precautions for parameter management and editing.
• Turn OFF the servo before you perform SERVOPACK parameter management or
editing.
• Never turn OFF the control power while performing SERVOPACK parameter man-
agement or editing.
• Do not use the SigmaWin for
Σ
-V-SD (MT) when performing SERVOPACK parame-
ter management or editing.