8 Servo Drive Management
8.2.1 Initial Settings for SERVOPACK Parameters and Preparation for Mass Production
8-4
8.2.1
Initial Settings for SERVOPACK Parameters and Preparation for Mass
Production
SERVOPACKs are shipped from the factory with factory settings for the parameters. Therefore, the parame-
ters must be set specifically for different types of machines.
(1) Setup for a New Machine Type
When the power supply is turned ON to a new type of machine for the first time, the parameters, such as the
direction of rotation or the stop method used when an alarm occurs, must be set for each SERVOPACK.
Write the parameter file for the spindle motor to the SERVOPACK that is used for the spindle axis with the
SigmaWin for
Σ
-V-SD (MT).
After the parameter file is written, calibrate the servos and set the gains for each axis.
(2) Uploading SERVOPACK Parameters and Saving as a File
Upload the SERVOPACK parameters that are used to set up each axis for the machine to the host controller.
Save the SERVOPACK parameters that are uploaded for each axis in a format that is compatible with the file
system of the host controller (e.g., ASCII text).