2017717_b•en•2016-11-01
We reserve the right to make technical changes
34
WAREMA climatronic® 3.x
Installation and connection
7.1 Switch actuator 4M/6M DP/EGN
Switch actuators 4M and 6M are electronic control devices for the potential-
free control of up to 4 or 6 sun shading drives or products. The switch
actuators are supplied with 24 V DC of power. The products can be supplied
either with 230 V AC or 24 V DC of power on separate terminal sets. The
connected drives are controlled by the WAREMA climatronic®, local control
with suitable operating elements is also possible.
To prevent damage to the connected motors, the default settings are such
that only one relay is activated at a time and connected single push buttons
operate in dead man's mode. Group buttons and locking contacts are
functional after the actuator has been commissioned.
Install the actuator as described in
chapter 4.4 on page 15
.
Use the
wiring diagram on page 40
to connect the actuator.
Also note the
chapter 5.6 Dimensioning of the power supply on page 30
,
as the actuator must be supplied with 24 V DC.
Detailed information on connecting can be found in the associated
installation instructions art. no. 890012.
7.2 Switch actuator 4M DP/EGN
The switch actuator 4MDC is an electronic control device for controlling up
to four sun shading drives with or without an incremental encoder. The switch
actuator and its downstream power consumer are supplied with 24 V DC.
The connected products are controlled via the WAREMA climatronic®;
an on-site control device with operating elements is also a possibility.
To operate the switch actuator 4MDC, a WAR MA climatronic® 2.0 control
panel or newer is needed.
To prevent damage to the connected motors, the default settings are such
that only one relay is activated at a time and connected single push buttons
operate in dead man's mode. Group buttons and locking contacts are func-
tional after the actuator has been commissioned.
Install the actuator as described in
chapter 4.4 on page 15
.
Use the
wiring diagram on page 42
to connect the actuator.
Also note the
chapter 5.6 Dimensioning of the power supply on page 30
,
as the actuator must be supplied with 24 V DC.
Detailed information on connecting can be found in the associated
installation instructions art. no. 2003272.