Relay test
(for Comfortrol programming unit)
Open flap:
Menu item
Key
³
SYSTEM
"
D
"
³
INSTALLER SETUP
"
C
"
³
CODE PLEASE
"
B
Ć
C
Ć
C
Ć
B
"
³
DIAGNOSIS
"
A
"
³
RELAY TEST
"
A
"
You can select the required relay
with menu item "CONTINUE"Ă"
A
"
and check its function.
Please note:
The programming unit must be
plugged into the control unit before a
relay test can be carried out.
Relays which have not been
mentioned are not relevant.
The burner stays off during the relay
test, if there is no heat demand.
Display
Meaning
01
ć Burner 1
st
Ăstage
N/A
<ST41> ON
02
ć Heating circuit pumpĂA
Circulation pump
<ST20> ON
03
ć Heating circuit pumpĂB
Heating circuit pump
<ST20B> ON
for extension kit with mixer
04
ć Cylinder loading pump
Three-way valve (DHW cyl. loading)
<ST21> ON
07
ć Mixer HCĂB
Mixer closed
*1
<ST52B> CLOSED
08
ć Mixer HCĂB
Mixer open
*1
<ST52B> OPEN
10
ć Modulation
Burner (lower output)
<ST90> CLOSED
Circulation pump
Burner
<ST41> ON
11
ć Modulation
burner (upper output)
<ST90> OPEN
Circulation pump
Burner
<ST41> ON
13
ć DHW circulation pump
DHW circulation pump
*2
<ST28> ON
14
ć Central fault message
Central fault message
*2
<ST50> ON
*1
Only with mixer extension kit, part no.Ă7450Ă058.
*2
Only with the connection extension, part no. 7404Ć582.
5692Ă485
G
B
Summary of Contents for Vitodens 200
Page 25: ...25 Initial start up inspection and maintenance 5692Ă485 GB ...
Page 96: ...96 Control unit for weather compensated mode with Comfortrol prog unit 5692Ă485 GB ...
Page 99: ...101 5692Ă485ĂGB ...
Page 105: ...109 Appendix Maint service Maint service Maint service Maint service 5692Ă485ĂGB ...
Page 107: ...111 Appendix Maint service Maint service Maint service Maint service 5692Ă485ĂGB ...
Page 109: ...113 Appendix Maint service Maint service Maint service Maint service 5692Ă485ĂGB ...