Control unit for weather-compensated mode with standard prog. unit
Summary coding levelĂ1
(cont.)
Coding in the
as delivered
condition
Address:value
Function mode
Code
change
Address:value
Possible change
Heating circuits
(cont.)
08:09
*1
Heating circuit without
mixer:
Heating curve
slopeĂ"
n
" set to "1.4"
08:00
to
08:15
Heating circuit without
mixer:
SlopeĂ"
n
" variable
between "0.2" and
"2.6"
22:00
Heating circuit
pumpĂ"ON" for heating
system designs
"04:02" and "04:03"
(connection to
plugĂ"20
Ă
A")
22:01
Heating circuit
pumpĂ"OFF" for
heating system
designsĂ"04:02" and
"04:03"
DHW cylinder
10:01
The circulation pump
starts immediately.
10:00
Circulation pump will
be switched on subject
to boiler temperature
13:00
Circulation pump with
run-on, up to max.
10Ămin
13:01
Circulation pump
without run-on
14:00
Set boiler water temp.
for DHW cylinder
loading acc. to set DHW
cylinder temp. +20ĂK
14:01
Set boiler water
temperature during
DHW cylinder loading
equals 78Ă
º
C
15:01
With DHW priority
control
15:00
Without DHW priority
control
21:00
Optional connection
DHW circulation pump
21:01
Output signal DHW
heating enabled (not
when operating with a
boiler circuit pump)
23:00
Setting range for DHW
temperature 32 to
60Ă
º
C
23:01
Setting range for DHW
temperature 52 to
80Ă
º
C
*1
Only for heating system designsĂ"04:02" and "04:03".
5692Ă485
G
B
Summary of Contents for Vitodens 200
Page 25: ...25 Initial start up inspection and maintenance 5692Ă485 GB ...
Page 96: ...96 Control unit for weather compensated mode with Comfortrol prog unit 5692Ă485 GB ...
Page 99: ...101 5692Ă485ĂGB ...
Page 105: ...109 Appendix Maint service Maint service Maint service Maint service 5692Ă485ĂGB ...
Page 107: ...111 Appendix Maint service Maint service Maint service Maint service 5692Ă485ĂGB ...
Page 109: ...113 Appendix Maint service Maint service Maint service Maint service 5692Ă485ĂGB ...