Control unit for weather-compensated mode with standard prog. unit
Summary coding levelĂ1
(cont.)
Coding in the
as delivered
condition
Address:value
Function mode
Code
change
Address:value
Possible change
Heating circuit pump
11:01
Heating circuit pump
speed for reduced
mode acc. to coding
addressĂ"044:_
Ă
_
Ă
_" of
coding levelĂ2
11:00
Heating circuit pump
speed for reduced
mode acc. to coding
addressĂ"046:_
Ă
_
Ă
_" of
coding levelĂ2
12:01
With variable speed
heating circuit pump
(automatic recognition)
12:00
Stepped heating circuit
pump
(e.g. transfer mode for
service)
16:01
With heating circuit
pump logic function
16:00
Without heating circuit
pumps logic function
17:00
Heating circuit without
mixer present
17:01
Heating circuit with
mixer present
Remote control
20:00
Without WS or RS
remote control unit
20:01
With WS or RS remote
control unit
*1
32:01
33:00
Weather-compensated
mode in heating and
reduced mode
32:00
*2
33:00
*2
With room temperature
hook-up in heating and
reduced mode
32:00
*2
33:01
*2
Weather-compensated
mode in heating mode
With room temperature
hook-up in reduced
mode
*1
The address is automatically set and must be manually reset.
*2
Do not adjust in the RS remote control connection.
5692Ă485
G
B
Summary of Contents for Vitodens 200
Page 25: ...25 Initial start up inspection and maintenance 5692Ă485 GB ...
Page 96: ...96 Control unit for weather compensated mode with Comfortrol prog unit 5692Ă485 GB ...
Page 99: ...101 5692Ă485ĂGB ...
Page 105: ...109 Appendix Maint service Maint service Maint service Maint service 5692Ă485ĂGB ...
Page 107: ...111 Appendix Maint service Maint service Maint service Maint service 5692Ă485ĂGB ...
Page 109: ...113 Appendix Maint service Maint service Maint service Maint service 5692Ă485ĂGB ...