Control unit for weather-compensated mode with standard prog. unit
Summary coding levelĂ2
(cont.)
Coding in the
as delivered
condition
Address:value
Function mode
Code
change
Address:value
Possible change
Boiler
(cont.)
125:000
Signal external
demand activated:
see the following table
125:001
to
125:011
Signal external
demand activated:
see the following table
Modification types coding addressĂ125 "External demand"
Coding
Heating
circuit
pump
Heating circuit with mixer
(extension kit)
Circulation
pump for
DHW cylinder
Boiler water
temperature
Heating circuit
pump
Mixer
y
loading
125:000
ON
OFF
Closed OFF
Will be
125:001
OFF
OFF
Closed OFF
maintained at
the set value
125:002
×
OFF
Closed OFF
the set value
acc. to coding
125:003
OFF
×
×
OFF
acc. to coding
address
"102"
125:004
ON
×
×
OFF
"102"
125:005
×
×
×
OFF
125:006
OFF
OFF
Closed ×
125:007
ON
OFF
Closed ×
125:008
×
OFF
Closed ×
125:009
OFF
×
×
×
125:010
ON
×
×
×
125:011
×
×
×
×
× = in a normal control function
5692Ă485
G
B
Summary of Contents for Vitodens 200
Page 25: ...25 Initial start up inspection and maintenance 5692Ă485 GB ...
Page 96: ...96 Control unit for weather compensated mode with Comfortrol prog unit 5692Ă485 GB ...
Page 99: ...101 5692Ă485ĂGB ...
Page 105: ...109 Appendix Maint service Maint service Maint service Maint service 5692Ă485ĂGB ...
Page 107: ...111 Appendix Maint service Maint service Maint service Maint service 5692Ă485ĂGB ...
Page 109: ...113 Appendix Maint service Maint service Maint service Maint service 5692Ă485ĂGB ...