77
Control unit for weather-compensated mode with standard prog. unit
Scanning temperatures
The programming unit enables the temperatures of connected sensors to be
scanned as set and actual values.
Scanning actual temperatures
1.
Select the ID of the respective
temperature from the table.
ID
Meaning of the display
Actual
temperature inĂ
º
C
(display example)
1
*1
Outside temperature
1:ăă8ą
º
C
2
Low loss header temperature
2:ă45ą
º
C
3
Boiler water temperature
3:ă63ą
º
C
4
*2
Flow temperature
4:ă44ą
º
C
5
*3
DHW cylinder temperature
5:ă50ą
º
C
7
*4
Room temperature
7:ă20ą
º
C
*1
The display value takes weather conditions into consideration, such as wind, solar
radiation and the wall temperature of the building.
*2
Only in connection with the extension kit for heating circuits with mixer.
*3
Only if the sensor is connected or activated.
*4
Only if the programming unit is set into the wall mounting fixture as room
temperature-dependent remote control unit.
2
. Press keyĂ"
?
" and turn the rotary
selectorĂ"
G
" anticlockwise or
clockwise, until the IDĂ
A
for the
corresponding temperature is
shown on the display.
At the same time the current
temperatureĂ
B
will be displayed.
5692Ă485
G
B
-
+
1-7
?
1 2 3 4 5 6 7
C
º
A
B
Summary of Contents for Vitodens 200
Page 25: ...25 Initial start up inspection and maintenance 5692Ă485 GB ...
Page 96: ...96 Control unit for weather compensated mode with Comfortrol prog unit 5692Ă485 GB ...
Page 99: ...101 5692Ă485ĂGB ...
Page 105: ...109 Appendix Maint service Maint service Maint service Maint service 5692Ă485ĂGB ...
Page 107: ...111 Appendix Maint service Maint service Maint service Maint service 5692Ă485ĂGB ...
Page 109: ...113 Appendix Maint service Maint service Maint service Maint service 5692Ă485ĂGB ...