Control unit for weather-compensated mode with Comfortrol prog. unit
Summary of coding addresses
(cont.)
Coding in the
as delivered
condition
Address:value
Function mode
Coding
change
Address:value
Possible change
Boiler
(cont.)
0B2:_
Ă
_
Ă
_
Fault memory
0B3:_
Ă
_
Ă
_
Fault memory
0B8:000
No DHW heating
0B8:001
0B8:002
*1
0B8:014
0B8:015
DHW cylinder
thermostat
Cylinder temperature
control (optimised)
Note the screed-drying
function acc. to two
selectable
temperatureĆtime
profiles.
Observe DINĂ4725Ć2.
Screed drying acc. to
temperature profileĂ
1
(DINĂ4725)
*2
Screed drying acc. to
temperature profileĂ
2
(ZVĂParquet and under-
floor technology)
*2
Days
1
5
15
25
10
10
20
20
30
30
40
50
Flow
temperature
º
C
1
2
*1
Automatic adjustment, if a DHW cylinder temperature sensor is connected, can be
manually changed to "001".
*2
After this function is completed, the system automatically changes over to the
operating mode "Heating and DHW".
5692Ă485
G
B
Summary of Contents for Vitodens 200
Page 25: ...25 Initial start up inspection and maintenance 5692Ă485 GB ...
Page 96: ...96 Control unit for weather compensated mode with Comfortrol prog unit 5692Ă485 GB ...
Page 99: ...101 5692Ă485ĂGB ...
Page 105: ...109 Appendix Maint service Maint service Maint service Maint service 5692Ă485ĂGB ...
Page 107: ...111 Appendix Maint service Maint service Maint service Maint service 5692Ă485ĂGB ...
Page 109: ...113 Appendix Maint service Maint service Maint service Maint service 5692Ă485ĂGB ...