Wall-mounted condensing boilers

 Installer’s and User’s instructions

EN

AUS

Hydroheat Supplies Pty Ltd
PO Box 1045, 6 Helen Kob Drive
Braeside VIC 3195
Ph 03 9588 1299  Fax 03 9588 2199

Summary of Contents for LUNA HT 1.1000

Page 1: ...Wall mounted condensing boilers Installer s and User s instructions EN AUS Hydroheat Supplies Pty Ltd PO Box 1045 6 Helen Kob Drive Braeside VIC 3195 Ph 03 9588 1299 Fax 03 9588 2199...

Page 2: ...ctives the safeguard of the environment the reliability and quality of its products and the health and safety of its employees Through its organisation the company is constantly committed to implement...

Page 3: ...mmended products for cleaning are SENTINEL X300 or X400 and FERNOX heating circuit restore To use this product proceeding strictly in accordance with the maker s directions 1 2 existing system Before...

Page 4: ...OMMISSIONING OF THE BOILER KEYS DISPLAY SYMBOLS Central heating mode setting key Data display reset key Parameter setting key increase value Parameter setting key decrease value Program access and scr...

Page 5: ...function which is identified by the appearance on the display of two black dashes under the symbol 4 Reset key In case of a fault referred to in point 3 7 Faults and resetting the boiler the boiler ca...

Page 6: ...et the central heating water temperature Press the keys to set the temperature required press either of the keys 1 or 10 figure 1 to save and return to the main menu NOTE With the outdoor sensor probe...

Page 7: ...ed by the factory the appliance is set up with the domestic hot water function always enabled and the domestic hot water programming function disabled The instructions for enabling this program are gi...

Page 8: ...y period of automatic central heating 0 00 00 00 24 00 P14 End of second daily period of automatic central heating 0 00 00 00 24 00 P15 Start of third daily period of automatic heating 0 00 00 00 24 0...

Page 9: ...or fumes thermostat or heating return temperature probe tripped press the reset key for about 2 seconds if this device is triggered repeatedly call the authorised service centre E111 Delivery tempera...

Page 10: ...we suggest you add some specific purpose anti freeze to the water contained in the system e g propylene glycole coupled with corrosion and scaling inhibitors The electronic management of boilers inclu...

Page 11: ...precautions The following remarks and instructions are addressed to Service Engineers to help them carry out a faultless installation In structions regarding lighting and operation of the boiler are...

Page 12: ...return pipework and under the boiler to collect the deposits and scaling which may remain and be circulated in the system after the purge When the boiler is fixed on the template connect the flue and...

Page 13: ...S INSTRUCTIONS PERTAINING TO THE INSTALLER Figure 6 0602_1002 CG_1786 11 BOILER SIZE Figure 5 MR G 1 1 2 heating flow RR G 1 1 2 heating return GAS G 1 gas inlet to the boiler SC condensation drain 06...

Page 14: ...chimney flue must be certified in accordance with the prEN 1856 1 Regulation C43 C83 The chimney or flue used must be suitable for the use WARNING To guarantee more operating insurance it is necessar...

Page 15: ...installation options 0310_0105 L max 10 m 0310_0106 Vertical flue terminal 110 160 mm installation options This type of installation can be carried out both on a flat or pitched roof by fitting a ter...

Page 16: ...nt air may be drawn in at a different site from where the flue terminal is located The splitting kit consists of an air cap 160 110 and of an air duct adaptor For the air duct adaptor fit the screws a...

Page 17: ...e the flue and air ducts are firmly fixed to the wall with suitable brackets To ensure the correct rated heat input to the maximum and minimum heat input it is necessary to update the speed rpm of the...

Page 18: ...5 400 G31 0 m 2 m 5200 100 1650 13 3700 35 140 2 m 6 m 5450 100 1750 13 5 3700 35 300 6 m 10 m 5750 100 1850 14 4050 40 400 GAS PIPES LENGTH L1 L2 m PARAMETERS P MAX HEAT OUTPUT MIN HEAT OUTPUT IGNITI...

Page 19: ...TPUT IGNITION LOAD H536 H613 rpm H541 H610 pwm H612 rpm H609 pwm H611 rpm H608 pwm Pa G20 0 m 2 m 6400 100 1850 11 3100 20 140 2 m 6 m 6650 100 1950 11 5 3900 25 300 6 m 10 m 6900 100 2050 12 4300 30...

Page 20: ...at the overall current drawn by accessories connected to the appliance is less than 2 A If the value is greater a relay must be wired between the boiler control circuit board and the accessories drawi...

Page 21: ...ALLER Figure 10 0902_1202 CT_0676 Terminal board Terminal board Terminal board Cover Cover 0603_1701 CG_1789 Expansion vessel Safety valve available optional extra P1 Low loss header pump P2 Heating c...

Page 22: ...c hot water precedence temperature sensor supplied as accessory for connecting heating only boilers to an external water heater The SIEMENS model QAA73 room temperature regulator optional accessory mu...

Page 23: ...40 15 72 HC1 max output Central heating system maximum output temperature 25 85 85 74 Type of building Light Heavy Light 75 Room compensation Activation deactivation of the influence of the room temp...

Page 24: ...graph 3 refers to the curve Kt 15 Increase the value displayed if the room temperature required is not reached inside the premises for central heating b with QAA73 room temperature control device The...

Page 25: ...in figure 11 The jumper present must be removed The central heating temperature is selected directly on the boiler control panel in accordance with the instructions provided for the user in this manua...

Page 26: ...ntrol circuit board and the pump Remove the resistor from terminals 9 10 of terminal strip M2 figure 12 and connect the hot water priority NTC sensor which is supplied as an accessory The sensing elem...

Page 27: ...ary to modify the control of pump P1 Configuration of parameter for electronic card H632 00000100 See 15 Figurr 12 STORAGE TANK CONNECTION DIAGRAM KEY UB DOMESTIC HOT WATER HEATER UNIT UR CENTRAL HEAT...

Page 28: ...natural gas to propane LPG the following operations must be performed before calibrating the gas valve as instructed above Replace the gas nozzle placed inside the gas valve flow gas connection To per...

Page 29: ...n the case of outlet ducts longer than 2 6 m set the values given in the charts of 12 1 Natural Gas 1 13kPa Propane Gas 2 75kPa CO2 max heat output 8 7 10 2 CO2 min heat output 8 4 9 8 Table 1 Gas con...

Page 30: ...cuit HC1 see Graph 1 15 H533 Selection of temperature curve of central heating circuit HC2 see Graph 1 15 H536 Maximum speed at maximum output in heating mode rpm maximum speed limitation Refer to par...

Page 31: ...e trip press the reset button positioned on the thermostat itself then press the release button on the boiler It is forbidden to disenable this safety device Flame ionization detector The flame sensin...

Page 32: ...ust flue duct to allow measurements of the combustion products hy gienic standards and combustion efficiency The second test point is connected to the comburant air inlet duct to check possible combus...

Page 33: ...the appearance and airtightness of the gaskets of the gas and combustion circuits check the state and correct position of the ignition and flame sensing electrodes check the state of the burner and m...

Page 34: ...hermostat 6 gas valve 7 flue water exchanger 8 flame detector electrode 9 burner 10 ignition electrode 11 gas mixture header 12 mixer with venturi 13 gas diaphragm 14 fan 15 flue thermostat 16 coaxial...

Page 35: ...35 910 024 1 EN AUS INSTRUCTIONS PERTAINING TO THE INSTALLER 22 ILLUSTRATED WIRING DIAGRAM CR_0309_GB 0911_2606 br brown bl black b blue r red g green g v green yellow w white CABLES COLOURS...

Page 36: ...25 7 29 kcal h 22 102 24 940 Reduced heat output 50 30 C kW 27 8 31 4 kcal h 23 908 27 004 Useful efficiency according to 92 42 CEE directive Central heating system max pressure bar 4 4 Water content...