XX091-01-01 Rev 902 AurorAcorD
Installation
•
3
Installation
Warning: Do not connect any unit to a power source until installation is complete.
ALARM
COM1
COM2
LOOPING 2
OUTPUT ONL
Y
12
10
9
11
16
14
13
15
VIDEO OUT
Up to 9
units per
IDL.
V1400X-IDL
V1400X-IDL
Dome
Rcvr.
Upgrade Cable
(product code 7721,
sold separately)
Host PC
Serial Port
RD
BK
OR
BL
W
BR
YL
G
Ground
Keyboard
Clock
+5 V Out
Keyboard
Data
RS-422
Comm Out –
RS-422
Resp In –
RS-422 Resp In +
or RS-232 RxD
RS-422 Comm Out +
or RS-232 TxD
Pin No.
Signal
Alarm 1-16
Normally open dry contact alarm
Ground
Dry contact alarm common
Normally closed dry contact alarm
1-16
19
20-35
36
37
RS-232/RS-422
Termination Box
(part # 1298-3140-01-00)
RD
BK
OR
BL
W
BR
YL
G
RS-485
Data +
N.C.
Ground
Keyboard
Clock
+5 V Out
Keyboard
Data
N.C.
RS-485
Data–
AurorANet Termination Box
(part # 1298-3190-01-00)
RS-232/RS-422 Termination Box
(part # 1298-3140-01-00)
NOTE: Internal jumpers and menu settings are set at
the factory for RS-232 on com1 and RS-422 on com2.
These defaults may be changed to use RS-232, RS-422
or RS-485 (2-wire AurorANet or 4-wire) on com1 or
com2. Menu settings must be changed as discussed in
the Programming chapter. Jumpers may or may not
need to be changed as discussed in the Reference
chapter. If you have not changed the factory default
jumper settings, you can use the AurorANet termination
box on com1 without changing jumpers. Otherwise,
remove appropriate jumpers before using the AurorANet
termination box as discussed in the Reference chapter.
Camera
Alarm Devices
Cable supplied
by installer.
120VAC and 230VAC
cables supplied
in accessory kit.
Total loop resistance
of this cable must be
less than 1 K
Ω
.
Connector and
pins supplied in
accessory kit.
Cable included in
AurorAcorD
Pre Pac
TO MONITORS
A2K
Video
1/9
A2K
Video
2/10
A2K
Video
3/11
A2K
Video
4/12
A2K
Video
5/13
A2K
Video
6/14
A2K
Video
7/15
A2K
Video
8/16
Terminate with 75 ohms at the destination devices. The Looping 2
connector provides outputs 9-16. Use the "A2K Video" labels for
outputs 9-16. Do not refer to the "Video" label.
For 230 VAC units, you
must replace the two 1.25 A
fuses with the two 0.63 A
fuses from the accessory kit.
Use 1.25 A fuses for 120
VAC units only
.