Installation
Installation
Page:
Page: 16
16
User
User Manual
Manual 450-GC
450-GC
Varian,
Varian, Inc.
Inc.
5.
5. Move the
Move the nut and
nut and ferrule to
ferrule to within 3
within 3 cm of
cm of column end.
column end.
6.
6. Measure
Measure the
the mark
mark point
point (see
(see Table 5
Table 5
) from the end of the column and mark
) from the end of the column and mark
this distance with a felt
this distance with a felt pen or typewriter fluid. The use
pen or typewriter fluid. The use of Column Scale
of Column Scale
tool (03-92575001, available in
tool (03-92575001, available in Capillary Column Quick Connect Kit
Capillary Column Quick Connect Kit
on
on
page 17
page 17
, 03-925751-90) or EZ-Grip
, 03-925751-90) or EZ-Grip
tm
tm
supplied with each standard GC
supplied with each standard GC
capillary column is highly recommended.
capillary column is highly recommended.
DO NOT allow the column nut and ferrule to fall past the mark
DO NOT allow the column nut and ferrule to fall past the mark
becau
because the ink or
se the ink or correction f
correction f luid c
luid c an contaminate the fe
an contaminate the ferrule.
rrule.
1041
1041
1061
1061
1177
1177
1079
1079 PTV
PTV
1093
1093
On-Column
On-Column
Insert
Insert depth
depth
Maximum*
Maximum*
Maximum*
Maximum*
3.7
3.7 cm
cm
7.5
7.5 cm
cm
8.6
8.6 cm
cm
Mark
Mark at
at
None
None
None
None
2.7
2.7 cm
cm
5
5 cm
cm
5
5 cm
cm
Table 5: Maximum insert depth for Capillary Column in Injector
Table 5: Maximum insert depth for Capillary Column in Injector
7.
7. * Only for
* Only for 1041 an
1041 and 1061In
d 1061Injectors, for the
jectors, for the other Injecto
other Injectors continue
rs continue at 12.
at 12.
8.
8. Gently push
Gently push the colum
the column fully u
n fully up into the
p into the Injector (9 cm
Injector (9 cm) until the
) until the column
column
comes to a firm
comes to a firm stop. This correctly positions the column against the upper
stop. This correctly positions the column against the upper
end of the Injector insert. The column must go in the full distance. If it goes
end of the Injector insert. The column must go in the full distance. If it goes
not, the Injector will
not, the Injector will not function properly. Tighten the column nut just
not function properly. Tighten the column nut just
enough to prevent column movement.
enough to prevent column movement.
9.
9. Manually in
Manually insert the syrin
sert the syringe that will
ge that will be used
be used with the co
with the column into
lumn into the 1041
the 1041
Injector, checking that the syringe goes into the Injector
Injector, checking that the syringe goes into the Injector completely with no
completely with no
binding or interference. If
binding or interference. If interference occurs, repeat the above column
interference occurs, repeat the above column
insertion procedure until the syringe moves smoothly into the Injector.
insertion procedure until the syringe moves smoothly into the Injector.
10.
10. Continue to hold the column firmly in place as you tighten the column nut
Continue to hold the column firmly in place as you tighten the column nut
carefully and only enough to hold the column firmly in place and obtain a
carefully and only enough to hold the column firmly in place and obtain a
good seal. Remove the syringe from the Injector.
good seal. Remove the syringe from the Injector.
11.
11. After the column is installed at the Injector end, make several dry injections
After the column is installed at the Injector end, make several dry injections
to ensure that the needle enters the column easily.
to ensure that the needle enters the column easily.
12.
12. Partially insert the column into the lower end of the Injector. Thread up the
Partially insert the column into the lower end of the Injector. Thread up the
capillary column nut and ferrule
capillary column nut and ferrule finger-tight.
finger-tight.
Summary of Contents for 450-GC
Page 92: ...AutoSamplers Page 152 User Manual 450 GC Varian Inc...
Page 144: ...Detectors Flame Ionization Detector FID Page 294 User Manual 450 GC Varian Inc...
Page 177: ...Maintenance Page 438 User Manual 450 GC Varian Inc...
Page 179: ...Shipping Cleaning and Disposal Instructions Page 440 User Manual 450 GC Varian Inc...
Page 201: ......