Detectors – Pulsed Flame Photometric Detector (PFPD)
Detectors – Pulsed Flame Photometric Detector (PFPD)
Page:
Page: 360
360
User
User Manual
Manual 450-GC
450-GC
Varian,
Varian, Inc.
Inc.
Insert the Column
Insert the Column
Refer for details
Refer for details on page 344
on page 344
.
.
These tools are needed to complete the following procedure
These tools are needed to complete the following procedure
Refer to parts and supplies
Refer to parts and supplies
,, on page 412
on page 412
..
••
Phillips-head
Phillips-head screwdriver.
screwdriver.
••
5/16"
5/16" wrench.
wrench.
••
Capillary
Capillary pick
pick or
or combustor
combustor support
support seal
seal extraction
extraction tool.
tool.
••
Ceramic
Ceramic scoring
scoring tool.
tool.
••
Magnifying
Magnifying lens.
lens.
••
3
3 mm
mm combustor
combustor extraction
extraction tool/Column
tool/Column Depth
Depth Gauge.
Gauge.
To Insert the Column Visually
To Insert the Column Visually
1.
1. Check tha
Check that the c
t the capillary co
apillary column nu
lumn nut and
t and the ferrule
the ferrule (reversed) a
(reversed) are installed
re installed
on the column as described in the manual. Check that approximately 20 cm
on the column as described in the manual. Check that approximately 20 cm
of the detector end of the column is free so that it can be inserted into the
of the detector end of the column is free so that it can be inserted into the
detector. If you are
detector. If you are reinstalling a used column, be sure that the burnt end
reinstalling a used column, be sure that the burnt end of
of
the column is trimmed off, leaving a
the column is trimmed off, leaving a clean, square end.
clean, square end.
2.
2. Insert the co
Insert the column into
lumn into the detector
the detector and pu
and push the colu
sh the column up u
mn up until it is
ntil it is
approximately 1 mm above the end of the combustor support. Tighten the
approximately 1 mm above the end of the combustor support. Tighten the
column nut to secure column in place. Next, proceed
column nut to secure column in place. Next, proceed on page 361
on page 361
..
To Insert the Column Using the Column Depth Gauge
To Insert the Column Using the Column Depth Gauge
To insert the column with Column Depth Gauge
To insert the column with Column Depth Gauge on page 361
on page 361
and follow
and follow
instructions through step 3, then proceed as follows:
instructions through step 3, then proceed as follows:
1.
1. Check tha
Check that the
t the capillary co
capillary column nu
lumn nut and
t and the ferrule
the ferrule (reversed) a
(reversed) are installed
re installed
on the column as described in the manual. Check that approximately 20 cm
on the column as described in the manual. Check that approximately 20 cm
of the detector end of the column is free so that it can be inserted into the
of the detector end of the column is free so that it can be inserted into the
detector. If you are
detector. If you are reinstalling a used column, be sure that the burnt end
reinstalling a used column, be sure that the burnt end of
of
the column is trimmed off, leaving a clean, square end.
the column is trimmed off, leaving a clean, square end.
2.
2. Insert the Co
Insert the Column Dep
lumn Depth Gaug
th Gauge into the
e into the hole from
hole from which the
which the combustor
combustor
was removed. Insert the column into the detector and push the column up
was removed. Insert the column into the detector and push the column up
until it begins to push up the depth gauge. Tighten the column nut gently
until it begins to push up the depth gauge. Tighten the column nut gently
until a small amount of force is required to move the column. Gently apply
until a small amount of force is required to move the column. Gently apply
force to the depth gauge to push the column down until the depth gauge
force to the depth gauge to push the column down until the depth gauge
Summary of Contents for 450-GC
Page 92: ...AutoSamplers Page 152 User Manual 450 GC Varian Inc...
Page 144: ...Detectors Flame Ionization Detector FID Page 294 User Manual 450 GC Varian Inc...
Page 177: ...Maintenance Page 438 User Manual 450 GC Varian Inc...
Page 179: ...Shipping Cleaning and Disposal Instructions Page 440 User Manual 450 GC Varian Inc...
Page 201: ......