RDA 400S
27.06.2011
ver.2
55
3.29 Operation test
Figure 3.66
To check the actual output, a running test can be performed. This is recommended especially when
the seed drill is new or is used on a different surface to the previous one.
When carrying out measurement, drive a distance (L) of 25 m with the RDA 400 S.
NOTE!
The fan should be turned off. The measured seed quantity multiplied by 100 gives the dos-
age in kg/ha.