RDA 400S
27.06.2011
ver.2
121
27 Seed box connection.
- This alarm is generated when seed shut-off does not
operate.
- Check the cable, switch and connection of the mag-
netic clutch in the seed box. An LED on the seed box
switch lights when the clutch receives current. The
clutch should then stop the feed roller. If the alarm is
generated although the LED lights, a likely cause is a
defective magnetic clutch.
28 Workstation not connected.
- Check whether the intermediate cable between the
Control Station and Workstation is connected. Inspect
the condition of the cable and connectors. The green
indicator lamp on the Workstation shows that voltage
is present, however, the lamp could light even though
the intermediate cable is partially damaged.
29 Voltage error Workstation 1.
- Workstation 1 receives a lower voltage than 11 V. In-
spect the connections and connectors of the interme-
diate cable. The function of the hydraulic valves, etc.
may cease to work.
30 Voltage error Workstation 2.
- Workstation 2 receives a lower voltage than 11 V. In-
spect the connections and connectors of the interme-
diate cable. The function of the hydraulic valves, etc.
may cease to work.
31 Seed level guard.
- Check the cable, connectors and connections of the
sensor.
- Check that the sensor is not dirty or damp. Dry the
sensor with a dry cloth.
- The sensor may be defective.
39 Speed sensor.
- Check the rpm sensor of the drive wheel transmission.
- Check the cable, connector and connection of the sen-
sor.
41 Hydraulic motor, seed out-
put.
- Is the hydraulic oil flow sufficient? Does the seed out-
put fan start?
- Check whether the seed boxes can rotate by hand.
- Check the cable, connector and connection of the sen-
sor.
- Check the operation of the sensor.
- Check whether the electric valve in the fan unit re-
ceives power.
Summary of Contents for Rapid RDA 400S
Page 2: ...2 27 06 2011 ver 2 ...
Page 4: ...4 ...
Page 16: ...Safety regulations 16 27 06 2011 ver 2 ...
Page 28: ...Instructions and settings 28 27 06 2011 ver 2 3 8 Horizontal alignment Figure 3 22 C B A ...
Page 89: ...RDA 400S 27 06 2011 ver 2 89 ...
Page 91: ...RDA 400S 27 06 2011 ver 2 91 Figure 5 4 ...
Page 97: ...RDA 400S 27 06 2011 ver 2 97 ...
Page 136: ...Appendices 136 27 06 2011 ver 2 ...
Page 137: ......