58
• VACON®
apfiff09 marine
Local contacts: http://drives.danfoss.com/danfoss-drives/local-contacts/
6.2 Reference Handling
6.2.1 Basic Settings
Code
Parameter
Min
Max
Unit
Default
Cust
ID
Note
P2.2.1
0
16
0
117
0
=AI1
1
=AI2
2
=AI1+AI2
3
=AI1-AI2
4
=AI2-AI1
5
=AI1xAI2
6
=AI1 Joystick
7
=AI2 Joystick
8
=Keypad
9
=Fieldbus
10
=Motor potentiometer
11
=AI1, AI2 minimum
12
=AI1, AI2 maximum
13
=Max frequency
14
=AI1/AI2 selection
15
=Encoder 1
16
=Encoder 2
P2.2.2
0
9
8
121
0
=AI1
1
=AI2
2
=AI1+AI2
3
=AI1-AI2
4
=AI2-AI1
5
=AI1xAI2
6
=AI1 Joystick
7
=AI2 Joystick
8
=Keypad
9
=Fieldbus
P2.2.3
0
9
9
122
See par. 2.2.2
P2.2.4
0
16
1
131
See
P2.2.5
Speed Share
-300.00
300.00
%
100.00
1241
P2.2.6
Load Share
0.0
500.0
%
100.0
1248
Table 6-2. Reference handling parameters, G2.2
6.2.2 Constant Reference
Code
Parameter
Min
Max
Unit
Default
Cust
ID
Note
P2.2.7.1
0.00
320.00
Hz
5.00
124
P2.2.7.2
0.00
320.00
Hz
10.00
105
Multi-step speed 1
P2.2.7.3
0.00
320.00
Hz
15.00
106
Multi-step speed 2
P2.2.7.4
0.00
320.00
Hz
20.00
126
Multi-step speed 3
P2.2.7.5
0.00
320.00
Hz
25.00
127
Multi-step speed 4
P2.2.7.6
0.00
320.00
Hz
30.00
128
Multi-step speed 5
P2.2.7.7
0.00
320.00
Hz
40.00
129
Multi-step speed 6
P2.2.7.8
0.00
320.00
Hz
50.00
130
Multi-step speed 7
P2.2.7.9
-320.00
320.00
Hz
2.00
1239
P2.2.7.10
Inching reference 2
-320.00
320.00
Hz
-2.00
1240
P2.2.7.11
-50.0
50.0
0.0
0.0
1252
VACON
®
NCDrive
speed tuning
Table 6-3. Contant reference parameters, G2.2.7
6.2.3 Power Reference
Code
Parameter
Min
Max
Unit
Default
Cust
ID
Note
P2.2.8.1
0
5
0
1620
Scaling from 0 to IDxxxx
0
=Not used