apfiff09 marine
VACON®
•
225
Local contacts: http://drives.danfoss.com/danfoss-drives/local-contacts/
Classified as Public
Master
(D1)
Follower
(D2)
Follower
(D3)
Follower
(D4)
Parameter
settings
Motor Nominal
Voltage
Motor Nominal
voltage from the
motor name plate
Motor Nominal
voltage from the
motor name plate
Motor Nominal
voltage from the
motor name plate
Motor Nominal
voltage from the
motor name plate
Motor nominal
Frequency
Motor Nominal
frequency from the
motor name plate
Motor Nominal
frequency from the
motor name plate
Motor Nominal
frequency from the
motor name plate
Motor Nominal
frequency from the
motor name plate
Motor Nominal
Current
Motor Nominal
current from the
motor name plate /
Number of drives in
parallel using
VACON
®
Drive
Synch
Motor Nominal
current from the
motor name plate /
Number of drives in
parallel using
VACON
®
Drive Synch
Motor Nominal
current from the
motor name plate /
Number of drives in
parallel using
VACON
®
Drive
Synch
Motor Nominal
current from the
motor name plate /
Number of drives in
parallel using
VACON
®
Drive Synch
Motor COS PHI
(Motor nominal
power factor)
Motor COS PHI from
the motor name plate
Motor COS PHI from
the motor name plate
Motor COS PHI from
the motor name
plate
Motor COS PHI from
the motor name plate
Motor Nominal
Power
Motor Nominal power
from the motor name
plate / Number of
drives in parallel
using VACON
®
Drive
Synch
Motor Nominal power
from the motor name
plate / Number of
drives in parallel
using VACON
®
Drive
Synch
Motor Nominal
power from the
motor name plate /
Number of drives in
parallel using
VACON
®
Drive
Synch
Motor Nominal power
from the motor name
plate / Number of
drives in parallel
using VACON
®
Drive
Synch
Master Follower
Mode
Master, DriveSynch
Follower, DriveSynch
Follower,
DriveSynch
Follower, DriveSynch
Motor Control
Mode (Open
Loop)
Open Loop
Frequency
If used as Secondary
Master: Open Loop
Frequency.
When used as
Follower: no meaning.
No meaning,
internally handled.
Recommended to
have same setting
as in master.
No meaning,
internally handled.
Recommended to
have same setting as
in master.
Motor Control
Mode (Closed
Loop)
Closed Loop Speed
/Torque
If used as Secondary
Master: Closed Loop
Speed/Torque.
When used as
Follower: no meaning.
No meaning,
internally handled
Recommended to
have same setting
as in master.
No meaning,
internally handled
Recommended to
have same setting as
in master.
Magnetizing
current
(needed only
for closed loop
motor control)
Motor nominal
magnetizing current /
Number of drives in
parallel using
VACON
®
Drive
Synch
Motor nominal
magnetizing current /
Number of drives in
parallel using
VACON
®
Drive Synch
Motor nominal
magnetizing current /
Number of drives in
parallel using
VACON
®
Drive
Synch
Motor nominal
magnetizing current /
Number of drives in
parallel using
VACON
®
Drive Synch
Switching
Frequency
Max 3.6 KHz
Same as in Master
Same as in Master
Same as in Master
Modulator Type 1, Software
Same as in Master
Same as in Master
Same as in Master
Follower Phase
shift (single
winding motor)
0 degrees
0
0
0
Follower Phase
shift (multiple
winding motor)
0 degrees
As per motor name
plate
As per motor name
plate
As per motor name
plate
Summary of Contents for apfiff09 marine
Page 1: ...vacon nx ac drives apfiff09 marine application manual ...
Page 2: ......
Page 310: ......