276
• VACON®
apfiff09 marine
Local contacts: http://drives.danfoss.com/danfoss-drives/local-contacts/
7.19.4
Threshold Value
The several statistical data points (mean, min, max and std) from the baseline data can be combined
one threshold value.
Threshold value = MeanFactor*mean + MinFactor*min + MaxFaxtor*max + StdFactor*stddev.
P2.19.3.3.1
Current Unbalance Mean Factor
ID3511
P2.19.3.6.1
Voltage Unbalance Mean Factor
ID3526
P2.19.4.2.1
Vibration Mean Factor
ID3550
P2.19.5.1.1
Load Mean Factor
ID3567
This parameter can be set mean factor in the threshold value if zero then mean is not
used.
P2.19.3.3.2
Current Unbalance Min Factor
ID3512
P2.19.3.6.2
Voltage Unbalance Min Factor
ID3527
P2.19.4.2.2
Vibration Min Factor
ID3551
P2.19.5.1.2
Load Min Factor
ID3568
This parameter can be set min factor in the threshold value if zero then min is not used.
P2.19.3.3.3
Current Unbalance Max Factor
ID3513
P2.19.3.6.3
Voltage Unbalance Max Factor
ID3528
P2.19.4.2.3
Vibration Mean Factor
ID3552
P2.19.5.1.3
Load Mean Factor
ID3569
This parameter can be set max factor in the threshold value if zero then max is not used.
P2.19.3.3.4
Current Unbalance Std Factor
ID3514
P2.19.3.6.4
Voltage Unbalance Std Factor
ID3529
P2.19.4.2.4
Vibration Std Factor
ID3553
P2.19.5.1.4
Load Std Factor
ID3570
This parameter can be set std factor in the threshold value if zero then std is not used.
P2.19.3.3.5
Current Unbalance Interpolation Type
ID3515
P2.19.3.6.5
Voltage Unbalance Interpolation Type
ID3530
P2.19.4.2.5
Vibration Interpolation Type
ID3554
P2.19.5.1.5
Load Interpolation Type
ID3571
The threshold value contains values for specific frequency points.
This parameter can be select interpolation type for the threshold values across frequency
points.