5.2.10
Counters
Below counter values are not visible as a standard monitoring signal but are accessible with
ID numbers from fieldbus.
5.2.10.1 Power On Time counter
This timer is counting when control board is powered (i.e. counting when only 24 Vdc is
given to control board).
ID10 PowerOnTimeTripCounter
Resettable power on time counter.
UINT value. READ only access.
Use ID1050 to define format.
Use ID1051 to reset value
ID1050 PowerOnTripCounterUnit
Read or select power on counter format.
USINT value. WRITE access.
1 = 1 ms
2 = 10 ms
3 = 100 ms
4 = 1 s
5 = 1 min
6 = 1 h (Default)
7 = 1 d
ID1051 ResetOnTimeTripCounter
Reset Power on trip counter, rising edge will reset counter.
BOOL value. WRITE access.
Write INT value 1 to reset if Process Data is used.
5.2.10.2 Energy Meter counter monitoring
ID11 EnergyMeter
Read ID80 and ID81 to see used format.
UINT value. READ only access.
ID82 EnergyMeterFormat
Decimal point place in the value
60 = 6 max number of digits, 0 fractional digits
61 = 6 max number of digits, 1 fractional digits
62 = 6 max number of digits, 2 fractional digits
UINT value. READ only access.
NOTE:
Most of the standard applications use ID number ID80 for this variable.
ID81 EnergyMeterUnit
Unit for the energy meter