296
• VACON®
apfiff09 marine
Local contacts: http://drives.danfoss.com/danfoss-drives/local-contacts/
F5
Charge switch
Charge switch status is not correct when start command is given.
S1 = Charge switch was open when START command was given.
•
Charge switch was open when the START command was given.
o
Check connection of the feedback from charging relay
o
Reset the fault and restart.
Should the fault re-occur, contact your local distributor.
F6
Emergency stop
Emergency stop command has been given by using a special option board.
F7
Saturation fault
S1 = Hardware failure
Possible cause and solutions
•
If there is a brake chopper in use
o
Check the isolation resistance and the resistance on the brake resistor.
•
FR4-FR8: Power module
o
Measure the power module directly from its terminals.
•
Hardware
o
Check the capacitors.
Summary of Contents for apfiff09 marine
Page 1: ...vacon nx ac drives apfiff09 marine application manual ...
Page 2: ......
Page 310: ......