• VACON®
apfiff09 marine
Local contacts: http://drives.danfoss.com/danfoss-drives/local-contacts/
6
= “U/f + Magn.Curr” –
U/f Curve and magnetization current
Shaft is rotated during identification.
This identification selection will not make a saturation curve identification and will open
the brake when the start rotation begins.
Because saturation curve run is not made, the running time is shorter and gives
possibility to make even if lifting hook is connected.
Example of behaviour
Parameters updated during this identification
- P2.1.9 MagnCurrent
- P2.8.4.2 U/f Ratio Select
- P2.8.4.5 U/f Mid Freq
- P2.8.4.6 U/f Mid Voltg
- P2.8.4.7 Zero Freq Voltg
- P2.8.9.16 RsVoltageDrop
- P2.8.9.17 IrAddZeroPVoltag
- P2.8.9.22-24 Ix Offset