286
• VACON®
apfiff09 marine
Local contacts: http://drives.danfoss.com/danfoss-drives/local-contacts/
10.1.2
Combination 2, ByPass
–
ProfiDrive; State Diagram
S5: Switching Off
SW.B0, B1 = TRUE | B2, B6 = FALSE
Power supply on
S1: Switching On Disabled
SW.B6 = TRUE | B0, B1, B2 = FALSE
S2: Ready For Switching On
SW.B0 = TRUE | B1, B2, B6 = FALSE
S3: Switched On
SW.B0, B1 = TRUE | B2, B6 = FALSE
S4: Operation
SW.B0, B1, B2 = TRUE | B6 = FALSE
CW.B0 = FALSE (OFF)
CW.B1= TRUE (No Coast Stop)
CW.B2 = TRUE (No Quick Stop)
CW.B1= FALSE (Coast Stop)
CW.B2 = FALSE (Quick Stop)
CW.B0 = TRUE (ON)
CW.B0 = FALSE (OFF)
CW.B3 = TRUE (Enable Operation)
CW.B3 = FALSE (Disable Operation)
CW.B1 = FALSE (Coast Stop)
CW.B1 = FALSE (Coast Stop)
OR
CW.B2 = FALSE (Quick Stop)
RAMP STOP
QUICK STOP
CW.B0 = FALSE
(OFF)
CW.B0 = TRUE
(ON)
CW.B2 = FALSE
(Quick Stop)
CW.B1 = FALSE (Coast Stop)
CW.B2 = FALSE
(Quick Stop)
Modulation
Stopped
Modulation
Stopped
Summary of Contents for apfiff09 marine
Page 1: ...vacon nx ac drives apfiff09 marine application manual ...
Page 2: ......
Page 310: ......