apfiff09 marine
VACON®
•
113
Local contacts: http://drives.danfoss.com/danfoss-drives/local-contacts/
Classified as Public
P2.2.4
I/O frequency reference selection 2
ID131
“I/O Reference 2”
This parameter is used to select different reference input location with digital input
P2.4.2.17 I/O Ref. 2. Selections for this are the same as for the I/O frequency reference
selection 1.
Other parameters related to function
-
Digital input P2.4.2.17 I/0 Ref. 1/2
P2.2.5
Speed share
ID1241
“Speed Share”
Defines the speed reference percentage ratio after the final reference location but before
the ramp control. The m
onitoring value “FreqReference”
shows the reference after the
speed share function. Used to adjust the reference ration, for example, in a line drive so
that the PLC can give the same reference to all drives while the speed share
compensate gear ratio affects the line speed.
P2.2.6
Load Share
ID1248
“Load Share”
Defines the percentage for final torque reference after the final torque reference location
selection but before the torque reference step function, torque reference dead zone and
reference filtering.