Use this parameter to set the duration of the baseline run.
P2.19.2.5 Modified Array
ID3506
Before or after baseline run each measuring point can be modified by parameter. This
parameter can be changed modified array.
0 = Freq Points
1 = Current Max Steady
2 = Current Min Steady
3 = Current Mean Steady
4 = Current Std Steady
5 = Voltage Max Steady
6 = Voltage Min Steady
7 = Voltage Mean Steady
8 = Voltage Std Steady
9 = Vibration Max Ramp
10 = Vibration Min Ramp
11 = Vibration Mean Ramp
12 = Vibration Std Ramp
13 = Load Max Steady
14 = Load Min Steady
15 = Load Mean Steady
16 = Load Std Steady
P2.19.2.6 Modified Point
ID3507
This parameter can be changed point in the modified array. Steady array includes 10
points and ramp array includes 9 points. First point is 0 value.
P2.19.2.7 Modified Value
ID3508
This parameter can be changed value in the modified point.
P2.19.2.8 Modified Activation
ID3505
Before or after baseline run each measuring point can be modified. Use this parameter to
activate the modified value ID 3508 of the modified point ID 3507.