7.6.3.3
Torque follower function
Torque follower function will keep the internal torque limit near the actual torque so that when the
torque demand increases, the increase rate is controlled by the torque limit increase rate parameter.
This function can be used together with the power limit ramp rate function because a low power limit
at low speed will give high torque and may cause mechanical stress in the system.
P2.6.3.6
Torque Follower ID1706
“Torque Follower”
Activates the torque follower function and ramp rate limiter function for torque limit.
0 =
Not used
1 =
Motoring
2 =
Generator
3 =
Mo Generator
P2.6.3.7
Torque limit increase rate
ID1532
“TorqueLimInc.rate”
Defines the torque limit increase rate. Decreasing power limit will be in effect
immediately.
P2.6.3.8
Torque limit follower hysteresis
ID1533
“TorqueFoll.Hyst”
Defines the hysteresis of the actual torque where the internal torque limit is kept while
the input torque limit is higher than the actual torque.
Input Torque
Limit
Torque limit
80 %
Internal
Torque Limit
Hysteresis
Actual
Torque