P2.5.1.14 External brake control ID445
“Ext Brake Contrl”
See detailed description about brake operation in G2.15 Brake Control.
External brake ON/OFF control
Example: OPTA2 board RO1 :
Brake function ON: Terminals 22-23 are connected (Relay is energized).
Brake function OFF: Terminals 22-23 are open (Relay not energized).
21
22
23
21
22
23
Note
: When power from control board is removed, the terminals 22-23 are open.
When using the Master Follower function, the follower drive will open the brake at the
same time as the Master even if the Follower's conditions for brake opening have not
been met.
P2.5.1.15 External brake control, inverted
ID446
“ExtBrakeCtrl,Inv”
See detail description about brake operation in G2.15 Brake Control
Example: OPTA2 board RO1 :
Brake function ON: Terminals 22-23 are open. (Relay not energized)
Brake function OFF: Terminals 22-23 are connected. (Relay is energized).
21
22
23
21
22
23
When using the Master Follower function, the follower drive will open the brake at the
same time as the Master does even if the Follower's conditions for brake opening have
not been met.
P2.5.1.16 Output frequency limit 1 supervision ID447
“FreqOut SupvLim1”
The output frequency goes outside the set supervision limits defined in Supervision Lim
parameter group. The function can be set to monitor either the high or the low limit. Limit
and functions are selected in G2.5.8 Supervision Limits.
Brake Open Command
Brake function OFF
Brake Close Command
Brake function ON
Brake Open Command
Brake function OFF
Brake Close Command
Brake function ON