YO99-0874-DI-002-18
36
Table. 9 Parameter setting: Mitsubishi FR-D720 series
Parameter No.
Parameter
PRC-003A PRC-006A PRC-012A PRC-018A
P1
Maximum frequency
60
P9
Electronic thermal O/L relay
3.6
9.3
15.1
21.0
P19
Base frequency voltage
200
P22
Stall prevention operation level
58.5
75.5
80.1
72.3
P57
Restart casting time
0
P67
Number
of
retries
at
alarm
occurrence
10
P68
Retry waiting time
6
P75
Reset selection/ disconnected PU
detection/ PU stop selection
1
P77
Parameter write selection
1
P78
Reverse rotation prevention selection
1
P79
Operation mode selection
3
P80
Motor capacity
0.75
2.2
3.7
5.5
P122
PU communication check interval
time
9999
P160
Extended function selection
0
P161
Frequency setting/key lock operation
selection
10
P180
RL terminal function selection
62
Mitsubishi FR-D720 series parameter settings Note
※
doing all parameter clear the ALLC] to 1. Parameter settings before
※
2.Pr77 to be set after the parameter settings of the other all over
※
that the settings after the 3.Pr77, to perform and hold the key lock the
[MODE] button
Summary of Contents for PRC-003A
Page 10: ...YO99 0874 DI 002 18 ix Fig 1 Warning Label PRC 003A PRC 006A PRC 012A PRC 018A...
Page 24: ...YO99 0874 DI 002 18 8 2 4 Dimensional drawing Fig 3 PRC 003A Dimensional drawing...
Page 25: ...YO99 0874 DI 002 18 9 Fig 4 PRC 006A Dimensional drawing...
Page 26: ...YO99 0874 DI 002 18 10 Fig 5 PRC 012A Dimensional drawing...
Page 27: ...YO99 0874 DI 002 18 11 Fig 6 PRC 018A Dimensional drawing...
Page 57: ...YO99 0874 DI 002 18 41 Fig 15 PRC 006A Optional attachment figure...
Page 58: ...YO99 0874 DI 002 18 42 Fig 16 PRC 012A Optional attachment figure...
Page 59: ...YO99 0874 DI 002 18 43 Fig 17 PRC 018A Optional attachment figure...
Page 76: ......