YO99-0874-DI-002-18
26
3.6 Electrical Connection
Table. 5 Electrical connection
Motor terminal board
Standard
U
V
W
E
Motor controller terminal board
Option
R
S
T
GND
Power
R
S
T
GND
Motor controller : refer to “APPENDIX 2 Option List”
Table. 6 Rated current value of the PRC series standard motor
Model
Motor output
(kW)
Rated current value (A)
200V, 50Hz
200V, 60Hz
220V, 60Hz
PRC-003A
0.75
3.5
3.3
3.2
PRC-006A
2.2
9.9
9.3
8.7
PRC-012A
3.7
15.5
14.9
13.8
PRC-018A
5.5
22.0
21.0
20.0
(1) Rated current value of the Motor shall vary subject to its mechanism. Use
the Electromagnetic breaker applicable to operate by the rated current
value of the applicable motor.
(2) Do the Direct-in start connection. The Star delta connection might have a
trouble in starting.
CAUTION
Refer to "
Table. 5
Electrical connection" to conduct the motor wiring.
Use crimping terminals for the connection and tighten screws. Check also any
loose on screws on the Motor.
Rotation direction is as shown in the Fig. 11.
Be sure also to put a safety circuit such as Electromagnetic breaker for the
electrical connection.
IMPORTANT
Summary of Contents for PRC-003A
Page 10: ...YO99 0874 DI 002 18 ix Fig 1 Warning Label PRC 003A PRC 006A PRC 012A PRC 018A...
Page 24: ...YO99 0874 DI 002 18 8 2 4 Dimensional drawing Fig 3 PRC 003A Dimensional drawing...
Page 25: ...YO99 0874 DI 002 18 9 Fig 4 PRC 006A Dimensional drawing...
Page 26: ...YO99 0874 DI 002 18 10 Fig 5 PRC 012A Dimensional drawing...
Page 27: ...YO99 0874 DI 002 18 11 Fig 6 PRC 018A Dimensional drawing...
Page 57: ...YO99 0874 DI 002 18 41 Fig 15 PRC 006A Optional attachment figure...
Page 58: ...YO99 0874 DI 002 18 42 Fig 16 PRC 012A Optional attachment figure...
Page 59: ...YO99 0874 DI 002 18 43 Fig 17 PRC 018A Optional attachment figure...
Page 76: ......