YO99-0874-DI-002-18
33
considering the voltage drop.
CAUTION
Wiring is long, please check the voltage drop across the wire, or conform to
the following calculated value. If there is a risk of the voltage drop, please
increase the size depending on the length of the cable wire.
Motor rated voltage (V) × 0.02
≧
Wiring distance √ 3 × wire resistance (Ω / km) × wire length (m) × motor rated
current(A) × 10 -3
※
Motor rated current, refer to "
Table 6
Rated current value of the PRC
series standard motor "
※
The wiring distance between the inverter and the motor, please be less
than or equal to 50 m.
5.4.1 Setting of Motor Controller (Atmospheric Pressure Actuating
Type)
There are Three kinds of inverters
[
FR-ER520 Series (Manufacturing before December,2004) and
FR-F520J Series (Manufacturing after December,2004) and FR-D720 Series (Manufacturing after
April,2009)
]
which use it by PRC Series. Please set it after confirming the model of the control equipment.
For the operation of the controller and electrical wiring, refer to the instruction manual for the inverter.
Troubles imputable to control by other than the standard controller and to
change of setting are not covered by this warranty.
Do not change the factory setting and starting control wiring (STF). When
starting the pump by remote operation, however, disconnect the shorting wire
of (STF) and turn ON/OFF the mechanical no-voltage contact to start/stop.
CAUTION
When you use the atmospheric actuation specification, in the control
equipment used in the PRC series, an appropriate setting for each pump
operation is performed. If you examine the special use method (When
changing the parameter of the control equipment), consult with our company.
Furthermore, this pump guarantees reliability by the operation frequency
50Hz
~
60Hz.
CAUTION
Summary of Contents for PRC-003A
Page 10: ...YO99 0874 DI 002 18 ix Fig 1 Warning Label PRC 003A PRC 006A PRC 012A PRC 018A...
Page 24: ...YO99 0874 DI 002 18 8 2 4 Dimensional drawing Fig 3 PRC 003A Dimensional drawing...
Page 25: ...YO99 0874 DI 002 18 9 Fig 4 PRC 006A Dimensional drawing...
Page 26: ...YO99 0874 DI 002 18 10 Fig 5 PRC 012A Dimensional drawing...
Page 27: ...YO99 0874 DI 002 18 11 Fig 6 PRC 018A Dimensional drawing...
Page 57: ...YO99 0874 DI 002 18 41 Fig 15 PRC 006A Optional attachment figure...
Page 58: ...YO99 0874 DI 002 18 42 Fig 16 PRC 012A Optional attachment figure...
Page 59: ...YO99 0874 DI 002 18 43 Fig 17 PRC 018A Optional attachment figure...
Page 76: ......