YO99-0874-DI-002-18
29
Fig. 11 Gear rotation direction
Never run the Vacuum pump on blocking up the exhaust outlet, putting any
device that hampers the gas passage or putting any oil mist trap not
conforming to the ULVAC pump. There is a risk that the pressure inside the
rises up as far as the Pump unit and/or Oil level gauge breaks or the Motor
gets overloaded.
This product is not made as the withstand pressure structure. Ensured
pressure value of the Pump shall be 0.03MPa (0.3kgf/cm
2
) (Gauge pressure).
If any valve was put to a pipe after the Exhaust outlet, check and ensure that it
is open.
WARNING
The Pump oil might deteriorate in a shorter time depending on the use.
It is recommended to replace the first Pump oil within ten days after operation
start and see how it got dirty to determine the oil replacement cycle.
CAUTION
Never fail to conduct the lubrication oil deaeration before starting operation
when lubricated anew the Mechanical booster pump or left it a long time after
lubrication.
Starting operation without deaeration might generate a lot f bubbles and cause
them flow in the Rotor chamber.
CAUTION
Never fail to flow the coolant during operation, Required coolant volume shall
be;
PRC-003A
→
2.0 L/min or more
PRC-006A
→
2.0 L/min or more
PRC-012AC
→
3.0 L/min or more
PRC-018AC
→
3.0 L/min or more
CAUTION
Summary of Contents for PRC-003A
Page 10: ...YO99 0874 DI 002 18 ix Fig 1 Warning Label PRC 003A PRC 006A PRC 012A PRC 018A...
Page 24: ...YO99 0874 DI 002 18 8 2 4 Dimensional drawing Fig 3 PRC 003A Dimensional drawing...
Page 25: ...YO99 0874 DI 002 18 9 Fig 4 PRC 006A Dimensional drawing...
Page 26: ...YO99 0874 DI 002 18 10 Fig 5 PRC 012A Dimensional drawing...
Page 27: ...YO99 0874 DI 002 18 11 Fig 6 PRC 018A Dimensional drawing...
Page 57: ...YO99 0874 DI 002 18 41 Fig 15 PRC 006A Optional attachment figure...
Page 58: ...YO99 0874 DI 002 18 42 Fig 16 PRC 012A Optional attachment figure...
Page 59: ...YO99 0874 DI 002 18 43 Fig 17 PRC 018A Optional attachment figure...
Page 76: ......