YO99-0874-DI-002-18
v
Transfer
Countermeasure to the earthquake
Inlet piping <Mounting>
Coolant piping <Mounting>
Power Supply wiring <Mounting>
You have a risk of giving damage to your back as the load larger than safety
standard shall be required to transfer the product.
Be sure to use the loading machinery (such as mobile crane) to lift up the
Pump or load it on the pallet and fix it with Jack and run the Pallet truck for its
transfer.
WARNING
There is a risk that the Pump lays down or slides and breaks peripheral units if
it was not correctly fixed. Be sure to give allowances to the vacuum piping,
cooling piping, and electric cables so that they absorber vibrations to prevent
them from breaking and/or dismantling.
WARNING
●
Check and ensure that any of hazardous energy is blocked before starting
the operation.
WARNING
●
Check and ensure that any of hazardous energy is blocked before starting
the operation.
WARNING
●
Check and ensure that any of hazardous energy is blocked before starting
the operation.
●
Entitled staff should conduct the wiring operation. Erroneous wiring work
might cause a fire.
●
Conduct the wiring operation correctly in compliance with laws and rules
concerning the safety (e.g. Fire Defense Law, Electric Equipment
Technology standard, Internal line cord) in the country and region you use
the product.
●
Ensure to have a correct grounding.
●
You are recommended further to install a dedicated Leak breaker. You have
a risk of getting electrical shock in case of failure or electric leakage.
●
It is imperative to put the Overload protection device. Otherwise it would
cause the motor burn out and/or fire.
Voltage drop calculation
:
√
3
×
wire resistance (
Ω
/ km)
×
Wiring length (m)
×
motor rated current (A)
×
10
-3
※
motor rated current, refer to "
Table 3
Performance specifications "
WARNING
Summary of Contents for PRC-003A
Page 10: ...YO99 0874 DI 002 18 ix Fig 1 Warning Label PRC 003A PRC 006A PRC 012A PRC 018A...
Page 24: ...YO99 0874 DI 002 18 8 2 4 Dimensional drawing Fig 3 PRC 003A Dimensional drawing...
Page 25: ...YO99 0874 DI 002 18 9 Fig 4 PRC 006A Dimensional drawing...
Page 26: ...YO99 0874 DI 002 18 10 Fig 5 PRC 012A Dimensional drawing...
Page 27: ...YO99 0874 DI 002 18 11 Fig 6 PRC 018A Dimensional drawing...
Page 57: ...YO99 0874 DI 002 18 41 Fig 15 PRC 006A Optional attachment figure...
Page 58: ...YO99 0874 DI 002 18 42 Fig 16 PRC 012A Optional attachment figure...
Page 59: ...YO99 0874 DI 002 18 43 Fig 17 PRC 018A Optional attachment figure...
Page 76: ......