C2-5000 Series Universal Scaler Operation Manual
109
and the two parts have to be 'bandwidth-limited' to avoid them interfering with
each other.
21.2.8 I can no longer adjust the Output image resolution.
When the unit is in Lock mode, the output resolution is fixed to be the same as
the Lock source input resolution. During this time the Output image menu item is
not adjustable.
21.2.9 There is no picture on the preview output.
Because the preview output is an unscaled output, insure that the connected
output device is capable of showing the resolution on the currently selected
preview input. Also note that if previewing a CV or YC source, you will need to
connect to the CV Preview and not the RGB Preview.
21.2.10 The picture on the video display is black and white.
Insure that all the cables are correctly connected. If you are using a PAL TV to
display the output then the unit may be providing resolution set to NTSC mode,
or vice versa.
21.2.12 The picture on the video display is green.
The Output image type is probably set to YUV mode, whereas you are
connecting to an RGB monitor.
21.2.13 The RGB input is selected but the image is rolling or pink.
Check the input setup and confirm that the input type and sync method is set
correctly. (Having YUV input selected, instead of RGBHV often causes this
problem).
Summary of Contents for C2-5000 Series
Page 1: ...C2 5000 Series Universal Scaler Operation Manual...
Page 2: ...C2 5000 Series Universal Scaler Operation Manual 2...
Page 4: ...C2 5000 Series Universal Scaler Operation Manual 4...
Page 105: ...C2 5000 Series Universal Scaler Operation Manual 105 C2 5100 5200 Block Diagram...
Page 115: ...C2 5000 Series Universal Scaler Operation Manual 115...