C2-5000 Series Universal Scaler Operation Manual
36
1024 x 768 60Hz
Preview Source [RGB1]
10.5 Lock
Source
The Lock Source function is where you tell the Scaler what input is to be used for
genlocking, Picture in Picture, Overlay and Underlay.
You can designate any input as the Lock Source, independent of your choice for
Program Source, however it only becomes active when the Lock Method (see
next function below) is set to something other than “Off”. Bear in mind that your
Lock Source choice controls the output image resolution so you will normally
want to make the Lock Source as high of a resolution as possible. Anytime the
Lock Source is something other than “Off”, the Output image is no longer
adjustable since it’s controlled by the characteristics of the chosen Lock Source.
The Lock Source display has the image information, as it’s top line. To select the
Lock Source, you park the LCD display on Lock Source by rotating the Menu
Select knob to the Lock Source screen and press the knob once. When the
brackets begin to flash, you rotate the Menu Select knob until your input choice
appears at which time you press the knob again. The selection is now stored in
memory and the brackets cease flashing.
The Lock Source LCD screen display looks like this:
1024 x 768 60Hz
Lock Source [RGB1]
10.6 Lock
Method
Lock Method determines what the Scaler will “do” with the Lock Source signal.
1024 x 768 60Hz
Lock Method [ Off]
The default position for Lock Method is “Off” and there are a total of five (5)
possible choices for this parameter. Once again, the top line shows the signal
characteristics and selections are made for the Lock Method are accomplished
using the Menu Select knob. When you are parked on this LCD screen, press the
Menu Select knob once and observe that the brackets flash. Make your selection
from the possibilities shown below and press the Menu Select knob a second
time to notify the Scaler of your choice. The brackets will stop flashing and your
choice will be stored in memory. The possible choices are:
Summary of Contents for C2-5000 Series
Page 1: ...C2 5000 Series Universal Scaler Operation Manual...
Page 2: ...C2 5000 Series Universal Scaler Operation Manual 2...
Page 4: ...C2 5000 Series Universal Scaler Operation Manual 4...
Page 105: ...C2 5000 Series Universal Scaler Operation Manual 105 C2 5100 5200 Block Diagram...
Page 115: ...C2 5000 Series Universal Scaler Operation Manual 115...