C2-5000 Series Universal Scaler Operation Manual
38
800 x 600 60Hz
Output Image [17] [RGBHV]
In the case of the default setting, the output is an RGBHV format signal with a
Horizontal and Vertical resolution of 800 X 600 Pixels respectively plus a refresh
rate of 60Hz. This is pre-defined output number 17 and was chosen as the
Factory Default because virtually all computer monitors, plasma screens and
projectors will accept this format without any problem. (Note that the Factory
Default is currently stored at memory position 17. If additional resolutions are
added in the future, the position may or may not be number 17 but the default
resolution is likely to remain at 800 X 600, 60 Hz for the foreseeable future).
There are many additional Output Image formats stored in memory and these
pre-determined formats could be augmented in the future allowing up to 1,000
different resolutions. It’s unlikely therefore that you will be unable to find a
suitable, high-resolution output to fit your needs.
Although they can be changed to other database entries, there are a number of
pre-defined outputs in the Scaler’s database. Pre-defined Output number 1 is for
NTSC Composite Video (CV) or YC (e.g. S-Video output) with a 60Hz vertical
rate. Pre-defined output number 2 is for PAL format with a 50 Hz vertical rate and
also steers the outputs to either CV or YC. (When you select Output 1 or 2, the
various RGB outputs are inoperative).
All the other Pre-defined outputs are for RGBHV, RGBS, RGsB (Sync on Green)
or YUV, also known as YCrCb, Y/R-Y/B-Y or YPbPr.
To change the Output characteristics, park the LCD display on the Output Image
screen and press the Menu Select knob once. The brackets surrounding the Pre-
defined output number will begin to flash. Select the Output type and
characteristic you want and press the knob once. If you have selected anything
except Pre-defined Outputs 1 or 2, you can then rotate the knob one detent to
the right, press the knob again and select RGBHV, RGBS, RGsB or YUV for the
output type. Press the knob to load your selection into memory. (Pre-defined
Outputs 1 and 2 have their resolution defaulted by design to conform to the
industry standards).
Summary of Contents for C2-5000 Series
Page 1: ...C2 5000 Series Universal Scaler Operation Manual...
Page 2: ...C2 5000 Series Universal Scaler Operation Manual 2...
Page 4: ...C2 5000 Series Universal Scaler Operation Manual 4...
Page 105: ...C2 5000 Series Universal Scaler Operation Manual 105 C2 5100 5200 Block Diagram...
Page 115: ...C2 5000 Series Universal Scaler Operation Manual 115...